CHELAN COUNTY PUBLIC UTILITIES DISTRICT NO. 1

Rock Island Dam, WA

100% of all welds Two (2) Upper and Two (2) Lower Stop Logs 

Original Construction, As-welded

Magnetic Particle (MT), Ultrasonic Testing (UT), Visual Testing (VT) and Paint Thickness Testing

Scott Speed, Mike Mehan, Clay Stevens

Location:

Area Inspected:

Surface Condition:

Inspection Method:

Inspector:

IMG_8143.JPG
IMG_8142.JPG
IMG_7968.JPG
IMG_7962.JPG

WISCONSIN ENERGY GROUP

Green Bay, WI

GE F7 Generator Exhaust System, Diffuser, Plenum, Silencers and Duct

As-welded

Visual Testing (VT), Direct

Mike Mehan

Location: 

Area Inspected:

Surface Condition:

Inspection Method:

Inspector:

IMG_4382.JPG
IMG_4339.JPG
IMG_20190312_113636840.jpg
IMG_0521.JPG

NORTHWESTERN ENERGY

Huron, South Dakota

Pratt & Whitney Turbine - Focus on plenum

As-welded

Visual Testing (VT), Direct

Guy Post

Location:

Area Inspected:

Surface Condition:

Inspection Method:

Inspector:

IMG_4702.JPG
IMG_4680.JPG
IMG_4764.JPG
IMG_4690.JPG

NUBS NOB SKI AREA

Harbor Springs, MI

Base of Tower 3

As-welded

Magnetic Particle (MP) and Liquid Penetrant (PT)

Mike Mehan

Location: 

Area Inspected:

Surface Condition:

Inspection Method:

Inspector:

IMG_20181029_112205724.jpg
IMG_20181029_094249050.jpg
IMG_20181029_084544886.jpg
IMG_20181029_083133522.jpg

DUROCHER MARINE

Cheboygan, MI

10-18"x18" Doubler Plates with 3/8 welds on three sides and 10 gusset plates

Original construction, as-welded

Magnetic Particle (MT) and Visual Testing (VT)

Scott Speed, Kurt LaLonde

Location:

Area Inspected:

Surface Condition:

Inspection Method:

Inspector:

IMG_0176.JPG
IMG_0174.JPG
IMG_0182.JPG
IMG_0175.JPG

CARMEUSE LIME & STONE

Rogers City, MI

Welding shaft

Repair weld, as-welded

Magnetic Particle (MT), Ultrasonic Testing (UT), and Visual Testing (VT)

Kurt LaLonde

Location: 

Area Inspected:

Surface Condition:

Inspection Method:

Inspector:

IMG_20180129_105527864.jpg
IMG_20180201_090756710.jpg
IMG_20180129_085930033.jpg
IMG_20180129_085940562.jpg

EAST JORDAN IRON WORKS

East Jordan, MI

Shop area - gears & shafts

Original

Penetrant Testing (PT) and Ultrasonic Testing (UT)

Mike Mehan

Location:

Area Inspected:

Surface Condition:

Inspection Method:

Inspector:

100_0325.JPG
100_0321.JPG
100_0315.JPG
100_0319.JPG

CRYSTAL MOUNTAIN SKI RESORT

Thompsonville, MI

Chairs on Loki, Clipper and Buck Lifts

Original Construction, As-welded

Magnetic Particle (MT) and Visual Testing (VT)

Guy Post

Location: 

Area Inspected:

Surface Condition:

Inspection Method:

Inspector:

IMG_1134.JPG
IMG_1135.JPG
IMG_1130.JPG
IMG_1120.JPG

SHEPLER'S MACKINAW ISLAND FERRY

Mackinaw Island, MI

Structural steel on Mackinaw Island dock modification

Original construction, As-welded

Visual Testing (VT)

Michael Mehan

Location:

Area Inspected:

Surface Condition:

Inspection Method:

Inspector:

IMG_20180517_080532354_HDR.jpg
IMG_20180517_075534806_HDR.jpg
IMG_20180517_080731601_HDR.jpg
IMG_20180517_075511225_HDR.jpg